Equipment for cleaning

Equipment for live cleaning by means of suction or damp cleaning with special fluid.
TRS NS Dry Cleaning Kit

TRS NS Dry Cleaning Kit

Cleaning work up to 1,000 V is permitted under the instruction of a competent, qualified electrician as per DIN VDE 0105-100 ""Operation of electrical installations"" generally and the accident prevention regulations of Germany's BGETEM ""Electrical installations and equipment"" observing DGUV Rule 3.
  • Based on DIN VDE 0680-3
  • Not suitable for use in wet weather conditions
  • For indoor and outdoor installations
  • Equipment for live cleaning by means of suction
  • For dry cleaning of cable distribution cabinets, open indoor installations and control cabinets
  • Specially adapted operating heads for intensive cleaning
  • Plug-in coupling system allows fast replacement of operating heads
  • Regulation of intake air in the handle section
  • Delivered in a suitable transport case

TRS MS Dry Cleaning Kit

TRS MS Dry Cleaning Kit

Cleaning work from 1 to 36 kV may be performed under the supervision of a competent, qualified electrician according to DIN VDE 0105-100 ""Operation of electrical installations"", observing the sections 6.3.1 to 6.3.12 and the accident prevention regulations of Germany's BGETEM ""Electrical installations and equipment"" observing DGUV Rule 3.
As per DIN VDE 0682-621.
  • Not suitable for use in wet weather conditions
  • For indoor and outdoor installations
  • Equipment for live cleaning by means of suction
  • For dry cleaning of transformers and switchgear installations
  • Transparent intake tubes for enhanced safety
  • Specially adapted operating heads for intensive cleaning
  • Plug-in coupling system allows fast replacement of operating heads
  • Delivered in a suitable transport case

FRS ZK MS Damp Cleaning Kit

FRS ZK MS Damp Cleaning Kit

Cleaning work from 1 to 36 kV may be performed under the supervision of a competent, qualified electrician according to DIN VDE 0105-100 ""Operation of electrical installations"", observing the sections 6.3.1 to 6.3.12 and the accident prevention regulations of Germany's BGETEM ""Electrical installations and equipment"" observing DGUV Rule 3.
  • Based on DIN VDE 0681-1 and DIN VDE 0682-621
  • Not suitable for use in wet weather conditions
  • For indoor and outdoor installations
  • Damp cleaning equipment for use under live conditions with special cleaning liquid
  • Universal gear coupling for replacing and adjusting the angle of operating heads
  • Rigid and flexible plug-in operating heads allow fast and easy replacement of the sponges
  • Delivered in a suitable transport case

TFRS MS Combined Cleaning Kit

TFRS MS Combined Cleaning Kit

Cleaning work from 1 to 36 kV may be performed under the supervision of a competent, qualified electrician according to DIN VDE 0105-100 ""Operation of electrical installations"", observing the sections 6.3.1 to 6.3.12 and the accident prevention regulations of Germany's BGETEM ""Electrical installations and equipment"" observing DGUV Rule 3.
  • Based on DIN VDE 0681-1 (damp cleaning)
  • In accordance with DIN VDE 0682-621 (dry cleaning)
  • Not suitable for use in wet weather conditions
  • For indoor and outdoor installations
  • Combined dry and damp kit for cleaning under live conditions
  • Transparent intake tubes for enhanced safety
  • Specially adapted operating heads for intensive cleaning
  • Universal gear coupling for replacing and adjusting the angle of operating heads
  • Rigid and flexible plug-in operating heads allow fast and easy replacement of the sponges
  • Delivered in suitable transport cases

Single Parts for MS Cleaning Kit

Single Parts for MS Cleaning Kit

Accessory for NS and MS Cleaning Kits

Accessory for NS and MS Cleaning Kits